Get EMC D-PEMX-DY-23 Dumps Questions [2024] To Gain Brilliant Result [Q70-Q92]

Share

Get EMC D-PEMX-DY-23 Dumps Questions [2024] To Gain Brilliant Result

D-PEMX-DY-23 dumps - Lead2PassExam - 100% Passing Guarantee

NEW QUESTION # 70
Where is a valid storage location for extracting the full MX7000 chassis logs package?

  • A. CSV
  • B. FTP
  • C. VMFS
  • D. CIFS

Answer: D


NEW QUESTION # 71
What location allows an administrator to enable DHCP for every iDRAC in the MX7000?

  • A. Chassis Landing Page > Settings > Network > iDRACs
  • B. Chassis Group Home Page > Compute > iDRAC Networking
  • C. Chassis Landing Page > Settings > Quick Deploy
  • D. Chassis Landing Page > Devices > Compute

Answer: C


NEW QUESTION # 72
How can a hard reset be performed on iDRAC?

  • A. Using the OME-M Interface and selecting Virtual Reseat
  • B. On the iDRAC web interface, select the Reset option
  • C. On the server, press and hold the ID LED button for 15 seconds
  • D. Using the RACADM command --SystemReset -t 0 -f

Answer: C


NEW QUESTION # 73
Which is an invalid option for the PowerEdge MX7000 control panel?

  • A. LED with QuickSync 2
  • B. LCD with QuickSync 2
  • C. LCD only
  • D. LED only

Answer: A


NEW QUESTION # 74
What is the number of server-facing ports and the bandwidth of each port on the MXG610s?
(Choose two.)

  • A. 16x 32 Gbps
  • B. 8x 32 Gbps
  • C. 8x 16 Gbps
  • D. 16x 16 Gbps

Answer: A,D


NEW QUESTION # 75
The MDB chassis tub assembly vertical distribution board provides connectivity to which chassis components?

  • A. Five near fan modules
  • B. Pear power supplies, compute sleds, Management Modules, and all fabric I/O modules
  • C. Power supplies, compute sleds, Management Modules, and two fabric I/O modules
  • D. Four cooling fans and four fabric I/O modules

Answer: D


NEW QUESTION # 76
A data center team is working on a solution to monitor and manage data center devices from anywhere.
Which feature can be configured to perform these tasks?

  • A. OIDC
  • B. QAT
  • C. OMM
  • D. OME-M

Answer: C


NEW QUESTION # 77
In an MX7000, which components are cooled by the rear fans?

  • A. Fabric A, B, and C IOMs only
  • B. All compute and storage sleds
  • C. Management Modules only
  • D. Fabric A, B, and C IOMs and the Management Modules

Answer: D


NEW QUESTION # 78
Which is the minimum iDRAC license required to use the Platform Restore feature of the Lifecycle Controller?

  • A. Express
  • B. Basic
  • C. Essentials
  • D. Enterprise

Answer: D


NEW QUESTION # 79
A system administrator must interface the compute sleds of an MX7000 chassis to a Z9432F-ON in a single SmartFabric.
Which FEM IOM is required?

  • A. MX5108n
  • B. MX7116n
  • C. MX9116n
  • D. MX8116n

Answer: D


NEW QUESTION # 80
A systems administrator must extract log files from an MX7000. The logs cannot be saved locally and must only be stored on a secure file server.
Which share protocols can they use to save the logs?

  • A. SFTP and CIFS
  • B. HTTPS and SFTP
  • C. CIFS and NFS
  • D. HTTPS and SCP
  • E. NFS and HTTPS

Answer: C


NEW QUESTION # 81
What configuration is supported for a fully populated MX740c compute sled?

  • A. 2 Fabric A mezz cards 2 Fabric B mezz cards
    2 Fabric C mini-mezz cards
  • B. 1 Fabric A mezz card
    1 Fabric B mezz card with Fabric C being integrated into the system board
  • C. 1 Fabric A mezz card 1 Fabric B mezz card
    1 Fabric C mini-mezz card
  • D. 1 Fabric B mezz card
    1 Fabric C mezz card with Fabric A being integrated into the system board

Answer: C


NEW QUESTION # 82
In addition to one compute sled, one management module, and one IOM, what is the minimum required HW configuration on the PowerEdge MX7000 to POST?

  • A. 1 power supply unit
    2 front cooling fans
    3 rear cooling fans
  • B. 2 power supply units
    4 front cooling fans
    5 rear cooling fans
  • C. 1 power supply unit
    1 front cooling fan
    1 rear cooling fan
  • D. 3 power supply units
    4 front cooling fans
    5 rear cooling fans

Answer: B


NEW QUESTION # 83
A customer is implementing a clustered three-chassis solution.
Which two components are required?
(Select 2)

  • A. MX9116n
  • B. MX7116n
  • C. Pass-Through module
  • D. MXG610s

Answer: A,B


NEW QUESTION # 84
At the initial release of the MX7000 for a daisy-chained configuration in a multi-chassis management group (MCM)m what is the maximum number of member chassis allowed, not counting the lead chassis?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C


NEW QUESTION # 85
A customer would like to periodically change the iDRAC root password on all the servers in their MCM Group.
What feature in OME-M should they use?

  • A. Chassis Deployment Wizard
  • B. Quick Deploy
  • C. Resource Pools
  • D. SupportAssist

Answer: B


NEW QUESTION # 86
To which component can a firmware update be applied without affecting any applications running on the server?

  • A. NIC
  • B. RAID Controller
  • C. BIOS
  • D. iDRAC

Answer: D


NEW QUESTION # 87
To which two components do the front fans of the MX7000 provide cooling?
(Select 2)

  • A. PSUs
  • B. MMs
  • C. Servers
  • D. IOMs

Answer: A,C


NEW QUESTION # 88
A server administrator wants to configure RAID on drives that are assigned to a compute sled.
Which interface can be used to complete the task?

  • A. OIDC
  • B. RAID Controller settings
  • C. iDRAC
  • D. Storage sled assignment

Answer: C


NEW QUESTION # 89
What is the maximum possible weight of a fully populated MX7000 chassis?

  • A. 400 Ibs (182 kg)
  • B. 300 Ibs (136 kg)
  • C. 250 Ibs (114 kg)
  • D. 500 Ibs (227 kg)

Answer: A


NEW QUESTION # 90
An administrator is asked to install and power-on a new MX740c sled in an MX7000 chassis. The administrator inserts the sled and presses the power button. They notice that the power button LED is blinking green. After a short time power button turns to solid green and the server finally turns on.
What operation was in progress when the power button was blinking green?

  • A. iDRAC was updating firmware
  • B. Lifecycle Controller was taking firmware inventory
  • C. iDRAC was booting
  • D. Lifecycle Controller update was in progress

Answer: C


NEW QUESTION # 91
Refer to the exhibit.

What is shown?

  • A. MX5016s
  • B. MXG610s
  • C. MX5108n
  • D. MX5000s

Answer: A


NEW QUESTION # 92
......

Get 100% Passing Success With True D-PEMX-DY-23 Exam: https://www.lead2passexam.com/EMC/valid-D-PEMX-DY-23-exam-dumps.html

Premium Quality EMC D-PEMX-DY-23 Online dumps: https://drive.google.com/open?id=16resbjo8b-aaiB0FA_FTzDIi52gPmJGX