Quality 010-151 PDF Dumps - 010-151 Exam Questions [Q45-Q64]

Share

Quality 010-151 PDF Dumps - 010-151 Exam Questions

Most UptoDate Cisco 010-151 Exam Dumps PDF 2021


Cisco 010-151 Exam Topics:

SectionWeightObjectives

Cisco UCS and Cisco NX-OS software operation

25%

1. Describe the Cisco Integrated Management Controller (CIMC)
2. Describe features and functionality of Cisco UCS Manager
3. Describe the different command modes for Cisco NX-OS software
4. Determine the current mode of the device
5. Verify the device configuration
6. Know how to use and interpret the basic Cisco NX-OS commands
7. Identify a configuration file from a Cisco device
8. Using the device file systems, directories, and files
9. Perform password recovery on a Cisco NX-OS switch device

Data Center Basics17%

1. Describe a data center
2. Describe cloud computing
3. Describe virtualization (server, network and storage)
4. Describe PCIe SSDs and NVMe
5. Describe raid storage
6. Differentiate between these Layer 2 technologies (Ethernet, Fast Ethernet, Gigabit Ethernet)
7. Describe SAN technology (SAN network type)
8. Describe SAN cabling (FCoE, PCIe)
9. Describe UTP and connectors
10. Describe fiber and connectors
11. Describe twinaxial and connectors
12. Describe SFP and QSFP transceivers

Cisco Equipment and Related Hardware

25%

1. Describe the Cisco Unified Computing System (UCS) components
2. Describe the Cisco UCS B-series Blade servers components and chassis layout
3. Describe the Cisco UCS C-series rack mount servers components and chassis layout
4. Describe Cisco UCS fabric interconnects and fabric extenders
5. Identify the Cisco UCS LED and chassis layout
6. Describe the Cisco UCS network adapters and expansion modules
7. Describe the Cisco UCS S-series Storage servers components and chassis layout
8. Describe the Cisco UCS E-series servers components and chassis layout
9. Describe the Cisco Nexus switches family components
10. Describe Cisco ACI and NX-OS mode
11. Describe the Cisco MDS 9700 product family components
12. Identifying the MDS 9700 Family Storage networking modules

Service-Related Information

33%

1. Use the hardware tools needed for repair
2. Make a physical connection from laptop to Cisco console port
3. Perform installation process steps and expected outcomes
4. Perform initial setup tasks
5. Service restoration verification
6. Perform remedial procedures on Cisco devices
7. Upgrade the BIOS on a Cisco UCS Server Blade with the GUI
8. Perform Cisco UCS Fabric Interconnect (FI) upgrade/downgrade procedure
9. Firmware Automatic Synchronization
10. Upgrade Cisco Integrated Management Controller firmware on a Cisco UCS Server C-Series
11. Troubleshoot Cisco UCS servers


 

NEW QUESTION 45
Which two blade servers support GPUs? (Choose two.)

  • A. UCS B420 M4
  • B. UCS B480 M5
  • C. UCS B260 M4
  • D. UCS B200 M4
  • E. UCS B200 M5

Answer: B,E

 

NEW QUESTION 46
Which supervisor module is supported by a Cisco Nexus 7700 Series Switch?

  • A. second-generation supervisor enhanced module (Sup2E)
  • B. first-generation supervisor module
  • C. second-generation supervisor module (Sup2)
  • D. third-generation supervisor enhanced module (Sup3E)

Answer: A

 

NEW QUESTION 47
Refer to the exhibit.

What is the name of this Cisco Nexus 3000 Series Switch?

  • A. Cisco Nexus 3132Q
  • B. Cisco Nexus 3016
  • C. Cisco Nexus 3524
  • D. Cisco Nexus 3172PQ

Answer: A

 

NEW QUESTION 48
Which cable is used to access the command-line interface of a Cisco UCS 6120XP Fabric Interconnects?

  • A. SFP+ Ethernet transceiver cable
  • B. KVM cable
  • C. Ethernet cable
  • D. console cable

Answer: D

Explanation:
Explanation/Reference:
corrected.

 

NEW QUESTION 49
Refer to the exhibit.

Which statement correctly identifies the front panel LEDs on the Cisco UCS C220 Server?

  • A. A is network link activity LED; B is system status LED; C is identification button and LED; D is power button and power status LED.
  • B. A is system status LED; B is network link activity LED; C is power button and power status LED; D is identification button and LED.
  • C. A is network link activity LED; B is system status LED; C is power button and power status LED; D is identification button and LED.
  • D. A is power button and power status LED; B is identification button and LED; C is system status LED; D is network link activity LED.

Answer: D

 

NEW QUESTION 50
Which group of UCS Virtual Interface Cards is exclusively designed for Cisco UCS C-Series Rack Server?

  • A. VIC 1440, VIC 1340, VIC 1388, VIC 1280, M81KR VIC
  • B. VIC 1455, VIC 1480, VIC 1385, VIC 1340, VIC 1280
  • C. VIC 1455, VIC 1497, VIC 1385, VIC 1387, VIC 1225
  • D. M81KR VIC, VIC 1497, VIC 1340, VIC 1387, VIC 1240

Answer: C

Explanation:
Explanation/Reference: https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/unified-computing-system- adapters/datasheet-c78-741130.html

 

NEW QUESTION 51
Refer to the exhibit.

Where is the best place to see whether the system is ready for a Fabric Interconnect failover?

  • A. A - Overall Status operable
  • B. B - L1 Connection
  • C. E - High Availability Details
  • D. C - Part Details
  • E. D - Access

Answer: C

Explanation:
Explanation

 

NEW QUESTION 52
Which SAN protocol uses Ethernet network without IP encapsulation?

  • A. FC
  • B. FCoE
  • C. iSCSI
  • D. IFCP
  • E. FCP

Answer: B

 

NEW QUESTION 53
Which two types of information does the show module NX-OS command display? (Choose two.)

  • A. Module IP address
  • B. Module type
  • C. Module status
  • D. Module ports type
  • E. Module license information

Answer: B,C

Explanation:
Explanation/Reference: https://www.cisco.com/en/US/docs/switches/datacenter/sw/4_2/nx-os/system_management/ command/reference/sm_cmd_show.html

 

NEW QUESTION 54
Refer to the exhibit.

What is the name of this rack-mount server?

  • A. Cisco UCS C460 Rack-Mount Server
  • B. Cisco UCS C420 Rack-Mount Server
  • C. Cisco UCS C240 Rack-Mount Server
  • D. Cisco UCS C220 Rack-Mount Server

Answer: B

 

NEW QUESTION 55
What is the maximum distance that the 40GBASE-LR4 Ethernet standard can span?

  • A. 10 km
  • B. 80 km
  • C. 550 m
  • D. 40 km

Answer: A

 

NEW QUESTION 56

Refer to the exhibit. Which item does B represent?

  • A. PCIe Riser 2
  • B. mLOM
  • C. PCIe Riser 1
  • D. Rear 2.5-inch drive bays
  • E. Power Supply

Answer: A

 

NEW QUESTION 57
Which Cisco UCS Virtual Interface Card Series is designed exclusively for the M5 generation?

  • A. VIC 1200 Series
  • B. M81KR VIC
  • C. VIC 1300 Series
  • D. VIC 1400 Series

Answer: D

 

NEW QUESTION 58
Cisco UCS 5100 Blade Server Chassis supports which two devices? (Choose two.)

  • A. E-Series Servers
  • B. Blade servers
  • C. S-Series Storage servers
  • D. Rack-mount Servers
  • E. Fiber Extenders

Answer: B,D

 

NEW QUESTION 59
If the Overall Status for a Cisco UCS B-Series Blade Server indicates a failure in the Cisco UCS Manager, such as discovery-failed, which statement is true?

  • A. The endpoints on that server cannot be upgraded.
  • B. The server is online, but the administrator cannot assign a service profile to that blade.
  • C. The server shuts down.
  • D. The server automatically reboots reboot in 3 minutes.

Answer: A

 

NEW QUESTION 60

Refer to the exhibit. Which item does 3 represent?

  • A. Operate as port lane switch button, port lane LEDs, and Layer 1 and Layer 2 ports.
  • B. Operate as 40-Gbps QSFP+ ports, and support QSA adapters to provide 1-Gbps to 10-Gbps operation
  • C. Operate as dedicated 40-Gbps, QSFP+ uplink ports.
  • D. Operate as 40-Gbps QSFP+ ports or as 4 x 10-Gbps SFP+ breakout ports

Answer: C

Explanation:
Explanation/Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/hw/6300-install- guide/6300_Series_HIG/6300_Series_HIG_chapter_01.html

 

NEW QUESTION 61
Refer to the exhibit.

What is the name of this Cisco Nexus 3000 Series Switch?

  • A. Cisco Nexus 3132Q
  • B. Cisco Nexus 3016
  • C. Cisco Nexus 3524
  • D. Cisco Nexus 3172PQ

Answer: A

 

NEW QUESTION 62
Which two statements about PCIe are true? (Choose two.)

  • A. A link that is composed of four lanes is called an x4 link.
  • B. The PCIe 4.0 standard doubles the transfer rate compared to PCIe 5.0.
  • C. The PCIe standard is a bus-based system in which all the devices share the same bidirectional, 32-bit or
    64-bit, parallel signal path.
  • D. You can install a PCI Express x16 adapter into an x4 slot.
  • E. The PCle supports native hot-swap functionality.

Answer: A,B

 

NEW QUESTION 63
Which three firmware components does the Host Upgrade Utility upgrade? (Choose three.)

  • A. Fabric Interconnect firmware
  • B. LAN on Motherboard
  • C. System BIOS
  • D. CIMC
  • E. Cisco UCS Manager

Answer: B,C,D

 

NEW QUESTION 64
......


To get more information visit:

Cisco Certified Technician Data Center (010-151) Exam Reference


How do you start to study for the Cisco Certified Technician Data Center (010-151) Exam

Get the guide For Cisco Certified Technician Data Center (010-151) Exam

Quick study guide if you don’t have time to read complete the page

The Cisco Certified Data Center Technician (CCT) validates the skills of a technician in the following areas;

  • The basic configuration of Cisco NX-OS
  • Cisco data center products and hardware with a focus on the Cisco Unified Computing System (UCS). The program covers repair (hardware failure solution) services on Cisco Data Center products, including hardware replacement, backup and recovery of software and configuration, verification of safety and environmental requirements, recognition of type in the required connection and cables and performs basic physical layer troubleshooting. The Cisco Certified Technician (CCT) must be competent in the following areas; basic configuration of Cisco NX-OS, Cisco Data Center products and hardware components. The Cisco certified technician must be able to perform repair (hardware failure) services on Cisco data center products, including backup and recovery of software and configuration, verify safety and environment requirements, recognize the type of connection and cable required and perform basic physical layer troubleshooting.

 

100% Free CCT Data Center 010-151 Dumps PDF Demo Cert Guide Cover: https://www.lead2passexam.com/Cisco/valid-010-151-exam-dumps.html

PDF Exam Material 2021 Realistic 010-151 Dumps Questions: https://drive.google.com/open?id=1LbkDrdIC8NuFr6k5PhpSu4GUM0oTRFvn